On this page
BS 5975 sets four design check categories, from Category 0 for standard solutions to Category 3 for complex designs checked by a separate organisation. The higher the risk and complexity, the more independent the check must be.
The four categories
| Category | Typical use | Who checks |
|---|---|---|
| 0 | Standard solutions from published guidance or manufacturer data | Another member of the site or design team |
| 1 | Simple designs | Another member of the same design team |
| 2 | More complex designs | An individual not involved in the design and not consulted by the designer |
| 3 | Complex or innovative designs | A separate organisation |
0
- Typical use
- Standard solutions from published guidance or manufacturer data
- Who checks
- Another member of the site or design team
1
- Typical use
- Simple designs
- Who checks
- Another member of the same design team
2
- Typical use
- More complex designs
- Who checks
- An individual not involved in the design and not consulted by the designer
3
- Typical use
- Complex or innovative designs
- Who checks
- A separate organisation
Choosing the category
The TWC and designer agree the category based on:
- Complexity of the design and the analysis needed
- Consequences of failure, including risk to the public
- Novelty of the solution
- Interfaces with existing structures or the permanent works
Typical Category 3 examples include facade retention, deep propped basements and large falsework schemes. Read about our Category 3 temporary works support.
Check certificates
Every check should produce a certificate recording the design, the checker, the category and any conditions. The certificate goes on the temporary works register before any permit to load is issued.
Common mistakes
- 1Category set too low to save time or cost
- 2Checks started after installation
- 3Changes on site made without returning to the designer and checker
Support in the North West
Matthews & Roberts coordinates temporary works design and checks for contractors in Liverpool, Manchester, Chester, Warrington and across the North West, alongside our temporary works design service. See also our BS 5975 guide.
Frequently asked questions
What is a Category 3 temporary works check?
A Category 3 check is for complex or innovative designs and must be carried out by a separate organisation from the designer.
Who decides the check category?
The Temporary Works Coordinator agrees the check category with the designer, based on the complexity and risk of the design.
What is a Category 0 check?
Category 0 applies to standard solutions where the design is taken from published guidance or a manufacturer's standard and checked by another member of the site or design team.
Temporary works
Related guides and templates
The category sets who checks the design. These cover the steps either side.
Guides
- BS 5975 Explained: The Contractor's Guide to Temporary Works ProceduresThe code of practice behind every temporary works procedure.
- Permit to Load and Permit to Strike ExplainedWhen to load or strike and who signs the permit.
- Who Is Responsible for Temporary Works on a Construction Site?Duties on multi contractor sites explained.
- Temporary Works Coordinator Appointment Checklist for ContractorsWhat to confirm before you appoint a TWC.
Free templates
- Temporary Works Register TemplateExcel register with categories, checks and permits.Free · Excel and PDF
- Temporary Works Coordinator Appointment ChecklistCompetence, appointment and systems checks for a TWC.Free · Word and PDF
- Permit to Load & Permit to Strike TemplatesPermit forms ready to issue on site.Free · Word and PDF
Need support with temporary works on your project?